Mostrar el registro sencillo del ítem

dc.contributor.authorSoler-López, Alejandro
dc.contributor.authorGarcía De Alcaraz Serrano, Antonio 
dc.contributor.authorMoreno-Villanueva, Adrián
dc.contributor.authorPino-Ortega, José
dc.date.accessioned2022-11-30T13:41:48Z
dc.date.available2022-11-30T13:41:48Z
dc.date.issued2022-11-23
dc.identifier.issn1424-8220
dc.identifier.urihttp://hdl.handle.net/10835/14107
dc.description.abstractAlthough there is a wide range of validated devices to measure vertical jump height, the degree of interchangeability among them is currently unknown. Aims: The purpose of this study was to examine the concurrent validity and reliability of multiple devices to measure jump height in men’s handball players. Methods: Sixteen players (age = 24.0 ± 3.7 years old) performed three types of jumps (n= 144—squat jump (SJ), countermovement jump (CMJ) and Abalakov jump (ABK)) on a contact platform (CHRONOJUMP®) while simultaneously being measured with two inertial devices (WIMU® and VERT®) and recorded with a high-speed camera. Vertical jump height was analyzed according to each type of jump. Results: The t-test showed statistically significant differences (p = 0.001) between the contact platform (reference standard) and the rest of the tools that tended to overestimate jump height in all jumps. SJ and CMJ proved to be the jump tests with the most stable reliability values in all devices (ICC: 0.92–0.98), except in the comparison with VERT®. Conclusions: Although all the analyzed devices proved to be valid and reliable in previous studies, they are not interchangeable. Therefore, it is suggested to always use the same type of device to evaluate vertical height jump.es_ES
dc.language.isoenes_ES
dc.publisherMDPIes_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectteam sportses_ES
dc.subjectstretch-shortening cyclees_ES
dc.subjectinertial deviceses_ES
dc.subjectwearablees_ES
dc.subjectmicrotechnologyes_ES
dc.subjecttestinges_ES
dc.subjectreproducibilityes_ES
dc.titleConcurrent Validity and Reliability of Devices to Measure Jump Height in Men’s Handball Playerses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherversionhttps://www.mdpi.com/1424-8220/22/23/9070es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.identifier.doi10.3390/s22239070


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional