Relative and Absolute Reliability of a Motor Assessment System Using KINECT® Camera
Ficheros
Identificadores
Compartir
Metadatos
Mostrar el registro completo del ítemFecha
2020-08-11Resumen
(1) Background: Virtual reality is currently useful in different clinical specialties as a diagnostic and therapeutic tool. In this study, we analyzed the relative and absolute reliability of the motor evaluation with the Kinect camera, a markerless motion system. (2) Methods: Observational study in healthy people, whose inclusion criteria were: healthy people, age 18 to 40 years old without pathologies or injuries in osteoarticular structures or ligamentous muscle and pharmacological treatment with influence on motor skills. Fifty-two subjects were evaluated. (3) Results: The results of the relative reliability were favorable in variables such as the amplitude of passage of the right leg (ICC (Intraclass Correlation Coefficient) = 0.95 ± 0.03), the step width of the left leg (ICC = 0.92 ± 0.04) or balance of the left leg (ICC = 0.90 ± 0.05). Moderate values were found for other variables. The absolute reliability, measured by the coefficient of variation, was favorable in most of the ...
Palabra/s clave
motor evaluation
reliability
Kinect camera