Refrigeration Capacity and Effect of Ageing on the Operation of Cellulose Evaporative Cooling Pads, by Wind Tunnel Analysis
Identifiers
Share
Metadata
Show full item recordDate
2019-11-25Abstract
This study investigates the temperature reduction capacity and water consumption of a fan-pad system installed in a greenhouse located in the coastal regions of Almería. The suitability of this system for coastal zones with high environmental humidity during the summer is analyzed. Historical temperature and relative humidity series are studied, obtaining the thermal difference and maximum, medium, and minimum monthly water consumption of the pads based on the operation data of the pads. Despite the high relative humidity of the air in the hottest hours of the day, a decrease of 5.92 °C in the mean temperature and a water consumption of 13.55 l/h per square meter of an evaporative cooling pad are obtained in the month of August. Additionally, the operation of a cellulose evaporative cooling pad installed for 3 years in a greenhouse is analyzed in a wind tunnel and compared with that of a new pad of the same model. Over time and with low maintenance, the porosity of the pad decreases du...
Palabra/s clave
greenhouse
evaporative cooling pad
refrigeration capacity