Mostrar el registro sencillo del ítem

dc.contributor.authorLópez Liria, Remedios 
dc.contributor.authorLópez Villegas, Antonio
dc.contributor.authorLeal Costa, César
dc.contributor.authorPeiró, Salvador
dc.contributor.authorRobles Musso, Emilio
dc.contributor.authorBautista Mesa, Rafael
dc.contributor.authorRocamora Pérez, Patricia 
dc.contributor.authorLappegård, Knut Tore
dc.contributor.authorCatalán Matamoros, Daniel Jesús 
dc.date.accessioned2020-03-02T11:52:23Z
dc.date.available2020-03-02T11:52:23Z
dc.date.issued2020-02-23
dc.identifier.issn1660-4601
dc.identifier.urihttp://hdl.handle.net/10835/7746
dc.description.abstractHealth-related quality of life (HRQoL) and functional capacity values immediately after pacemaker (PM) implantation have been well established; however, not much has been known about its long-term effects. The present study compared the long-term effectiveness and safety of remote monitoring plus a clinic visit versus clinic visits alone during follow-up of adults implanted with PMs. This study was a single-centre, controlled, non-randomised, non-blinded clinical trial. Data were collected pre-implantation and after 60 months. The patients in the PONIENTE study were assigned to two different groups: remote monitoring (RM) and conventional monitoring (CM). The EuroQol-5D (EQ-5D) questionnaire was used to assess HRQoL and Duke Activity Status Index was used for the functional capacity. After five years, 55 patients completed the study (RM = 21; CM = 34). EuroQol-5D and functional capacity values were improved; however, significant differences were observed only in the EQ5D visual analogue scale (p < 0.001). Remote monitoring was equally feasible, reliable, safe, and clinically useful as CM. The frequencies of rehospitalisations and emergency visits did not differ between the groups. RM was found to be safe and effective in early detection and treatment of medical- and device-related events and in reducing hospital visits. Improved HRQoL was described not only immediately after PM implantation but also extended over a long time.es_ES
dc.language.isoenes_ES
dc.publisherMDPIes_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjecthealth-related quality of lifees_ES
dc.subjectlong-term follow-upes_ES
dc.subjectremote monitoringes_ES
dc.subjectpacemakeres_ES
dc.subjecttelemedicinees_ES
dc.titleEffectiveness and Safety in Remote Monitoring of Patients with Pacemakers Five Years after an Implant: The Poniente Studyes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherversionhttps://www.mdpi.com/1660-4601/17/4/1431es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional