TY - GEN AU - Molina Aiz, Francisco Domingo AU - Valera Martínez, Diego Luis AU - Peña Fernández, Ana Araceli AU - López Martínez, Alejandro PY - 2009 SN - 1537-5110 SN - 1537-5129 UR - http://hdl.handle.net/10835/14688 AB - The wind coefficient of an Almeria-type greenhouse has been calculated from direct estimation of airflow at the openings by means of three-dimensional sonic anemometry. Measurements were taken with a strong northeast wind (Levante) and with a weak... LA - en TI - A study of natural ventilation in an Almeria-type greenhouse with insect screens by means of tri-sonic anemometry DO - https://doi.org/10.1016/j.biosystemseng.2009.06.013 ER -